EP010031 EP1M/31
EP010032 EP1M/32
EP010033 EP1P/33
EP010035 EP1M/35
EP1M/35A
EP1M/35B
EP010036 EP1/36
maintained power supply for use with the Masthead Control
Terminal (2), EP1M/29. Power requirements 240V AC.
PN3/54. Sub-units CD2/25, PS2/267. DD 1981.
Transcoder Monitoring Equipment. Monitors status of two
transcoders.
Checks
voltages
and
temperatures.
Gives
warning and Alarms. Outputs video display for each
Transcoder.
Power
requirements
240V AC.
PN3/ 54.
Sub-
units
PS2/187H,
PS4/9A,
GE8/505 x 2,
UN27 /1,
UN26/31,
UN23/130 x 2, C01/12, C08/12. DD 1982. DDHB 1.171(82).
Switching Command and Acknowledgement Equipment. Takes
command instructions from a control panel and translates
these commands to implement a pattern of waveguide switch-
ing appropriate to the command. Receives acknowledgements
of the waveguide switch positions and converts these switch
patterns to a light display on the panel consistent with
the issued command, or with an acknowledgement failure,
gives error indications. Power requirements 240V AC, 70 VA
max. PN3/54. DD 1982.
Data Distribution Terminal Equipment. Data Terminal for
Transmission Department Maintenance Teams. Receices 75kHz
FSK Data from B 11 Carrier or Line-Data. Produce printout
data relative to the teams area on request. Microprocessor
Based
System.
Power requirements 240 AC mains.
Reduced
PN3/54 with Plastic Cheeks and Carrying Handles. Sub-units
PS2/184, DM4/1, UN26/52, UN27/7 (2 off). DD 1982. DDMI
2.474(83). DDHB 2.500(84). DDTM 2.512(86) (Software).
Monitoring and Control Equipment. 19 inch 4U rack housing
a Zeus based system for the monitoring and control of a
suitable operational panel. The unit takes up to 144
momentary action switch inputs, 6 keyswitch inputs, 12
clock inputs to 10 bit counters and 6 clock inputs to 8 bit
counters. Buffered I/O to remote units is provided. Power
requirements 240V a.c. PN3/54. Parent equipment EP5/52
and EP5/519. Sub-units 2 x PS4/18A, UN26/31, UN27/7,
UN27/1, UN26/58, UN23/130, 2 x UN23/153, 3 x UN23/155, 3 x
UN23/156. DD 1983.
Monitoring and Control Equipment. 19 inch 4U rack housing
a ZEUS based system for the monitoring and control of an
operational panel. The unit takes up to 144 momentary
action switch inputs, 6 keyswitch inputs, 12 clock inputs
to 10 bit counters and 6 clock inputs to 8 bit counters.
Buffered I/O to remote units is provided. Power
requirements 240 Vac. PN3/54. Parent equipment Effects
Workshop Equipment EP5/520. Sub-units 1 x PS4/18A,
UN26/31, UN27/7, UN27/1, UN23/130, 2 x UN23/153, 2 x
UN23/155, 2 x UN23/156. DD 1983.
Monitoring and Control Equipment. As per EP1M/35A but sub-
units customised for use with EP5/521 Effects Mixing
Equipment. Power requirements 240 V ac. PN3/ 54. Parent
equipment EP5/521. Sub-units PS4/18A, UN23/153 x 2,
UN23/155 x 2, UN23/156 x 2, UN26/31, UN26/59, UN23/130,
UN27/1, UN27/7. DD 1984. DDHB 8.425(84).
Electra10g Interface. The Electralog Interface provides an
interface between Electra (RD4/509) and the Electralog
86