PSOl0047 PSl/47
PSOl0049 PSlM/49
PSOl0050 PSI/50
PSOl005l PSI/51
PSOl0052 PSI/52
PSOl0053 PSl/53A
PSl/53B
PSl/53C
PSOl0054 PSl/54A
PSOl0055 PSI/55
Power Supply. Provides the entire power requirement of
RP2/l0. Fits inside the rear of the crate AM16M/16.
Provides +140V 5mA; +36V unregulated O.5A; +32V regulated
0.22A; +9V unregulated lA; +5V regulated lA; 10.5 V a.c.
1.75A unregulated. Power requirements 240V :!::6%. Custom
aluminium panel 360mm x 2l0mm. DD 1978.
Power Supplier. Contains 2 off PS2/274 Power Suppliers
plus maintaining unit PS5/5 for use in CAR Sub-router
project. Power requirements 2l0-260V ac at 250 VA.
PN3A/54/55. Sub-units 2 off PS2/274t 1 off PS5/5. DD
1981.
Standby Battery Power Supplier. Provides a regulated 5V
supply to maintain memory contents in RDlM/l in the event
of mains failure. Contains 7 sealed Ni-Cad cells of 4 Amp
Hour capacitYt which are trickle-charged during normal
operation.
Power
requirements +18V.
CH1!64A.
Parent
equipment RDlM/l. DD 1982.
Master Unit. The unit provides current limited 24V and
logic control (DC switching) to SE2/24 (Line Changeover)t
SE2/25 (Line Changeover Slave) and SE5/l3 (Data Interface)
units as used with PCM stereo transmitter equipment. Fault
indication inputs are matrixed to four fault report
outputs. Power requirements 24v A&B. CHl/64A. Parent
equipment SE2/24t SE2/25t SE5/l3. TCPD 1982.
Battery Maintained Power Supplier. This unit regulates
+12 V failing the NiCad battery will support the output at
3 V (approx) for 100 mA hours. The +5 V input will support
the output at 4.4 V (approx) in the event of the +12 V only
failing. Power requirements +5 Vt +12 V. Parent equipment
EPlM/39At EPlM/4l. DD 1984.
Power Supply Cabinet. Power supply cabinet for use in OB
support vehicles. From 240 V ac input t it delivers 240 V
ac supply feeds and 24 V dc feeds for vehicle internal
services. Power requirements: 240 V ac plus standby 24 V
dc. D & ED 1986.
Power Supply Cabinet. Power Supply Cabinet for use in O.B.
support vehicles similar to PSl/53At but modified for
welfare facilities. Power requirements: 240 V ac plus
standby 24 V dc. D & ED 1986.
Power Supply Cabinet. Power Supply Cabinet for use in O.B.
support vehicles. Similar to PSl/53At but modified for
lighting only facilities. Power requirements: 240 V ac
plus standby 24V dc. D & ED 1986.
Power Supply Cabinet. Power supply cabinet for use in OB
support vehicles. From 240 V ac inputt it delivers 240 V
ac supply feeds and 12 V dc feeds for vehicle internal
services. Power requirements: 240 V ac plus standby 12 V
dc. D & ED 1986.
Power Supply Box. Power Supplier used on OB semi-trailers
to provide 24V t 6A unsmoothed dc for lighting and
auxiliaries. Die-cast weather-proofed box for external
227

27