PA6/97C
PA060098 PA6/98
PA060099 PA6/99A,B
PA060100 PA6/100
PA060101 PA6/101
PA060102 PA6/102
PA060103 PA6/103
PA060104 PA6/104
PA6/104A
transmitter status in mimic diagram form and controls
transmitter start and drive changeover functions. Output
relevant data to TMI automatic fault reporter. A second
unit may be slaved off the first to increase capacity to 4
transmitter services. This second unit is the PA6M/97B.
Power requirements 2 a.c. mains supplies. PN3/S4.
Equipment
superseded
PA6M/70.
Sub-units
UN23/101,
UN12/102, UN12/103, UN26/20 and UN12/1S. DD 1978. DDTM
2.442(79).
MF CIP. Control and Indication Panel for MF transmitters.
This is a version of the PA6M/97A Band 11 CIP, modified for
MF use. May be used with appropriate UN12/20A display
panel to provide mimic diagram displays for up to 4
transmitters. A second unit may be slaved off the first to
increase the capacity to 8 services. Power requirements
2 x a.c.
mains
(A+B
supplies).
PN3/S4.
Sub-units
UN23/102A, UN23/103, UN26/20, PS4/4A, UN12/20A. DD 1981.
Data Entry Control Panel
controlling SYPHER 2
requirements +SV at lA.
DD 1979. DDHB 7.290(81).
for data entry into synchronising
sound dubbing suite. Power
Sub-units UN23/118 and UN23/119.
Colour Balance Control Panel. 'A' version colour balance
control panel for remote control of RED, GREEN and BLUE
lifts and gains. Uses continuously rotatable edge operated
wheels generating pulses processed by UN26/21 and UN23/104.
Used on CMCR type S's. 'B' version as 'A' version but for
left hand operator. 18Smm x 161mm. SCPD 1979.
6 Channel Outside Source Mixer Panel. OdB in Mono; -3dB
out stereo; 6 clean feeds and prehear monitoring included;
re-set gain; Channel fader and pan pot on each channel
intended for use with UN1/173 Telephone Control and Balance
Units. 24V approximately 300mA. CHl/77B. Sub-units 7 x
AMS/1S, 7 x AMS/19 and AM20/3. SCPD 1979.
Sound Routing Panel. Provides remote control of a sound
routing matrix, and indications of selected routings.
Power requirements +SV, +12V. PN3/S8 (modified). DD
1979.
Vision Routing Panel. Provides
routing matrix, and indications
Power requirements +SV, +12V.
1979.
remote control of a vision
of the selected routings.
PN3/38
(modified).
DD
Link Control and Alarm Panel. Provides push-button control
for various functions in a remotely-operated masthead
receiver system.
These and other system features are
monitored by various displays on the panel. Power
requirements +SV, +12V. PN3/S8 (modified). DD 1979.
Monitroing Selection Panel. Illuminated push-buttons
provide monitoring selection and indication. Power
requirements +12V. 1U Panel. DD 1979.
Monitroing Selection Panel. Illuminated push-buttons
provide monitoring selection and indication. Power
requirements +12V. 1U Panel. DD 1980.
203

3